Raritan PX3-4700YU-V2 power distribution unit (PDU) 30 AC outlet(s) 0U Black

Raritan PX3-4700YU-V2. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. LED indicators: Status. Monitoring: Humidity, Temperature. Nominal input voltage: 415 V, Maximum current: 80 A, AC input frequency: 50 - 60 Hz
Manufacturer: Raritan
SKU: 5850043
Manufacturer part number: PX3-4700YU-V2
$4,259.00
Monitored rack power distribution unit (0U [vertical], 57.5kVA, 30 outlets). INPUT: 415v (3-phase WYE), 80a - Hardwired [AC Terminal Block, No Cord]; OUTPUT: 12@ C13, 18@ C19 outlets; on 18@ 1-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 71mm x 89mm x 2030mm (2.8in x 3.5in x 79.9in). Max Weight 12 kg. Maximum ambient temperature 60C at full load.

 

  • Removable Controller
  • Securelock
  • Embedded Processor: ARM Cortex A5 500MHZ (Atmel A5D21C), 16MB SPI Flash, 128MB DDR2 RAM
Monitored rack power distribution unit (0U [vertical], 57.5kVA, 30 outlets). INPUT: 415v (3-phase WYE), 80a - Hardwired [AC Terminal Block, No Cord]; OUTPUT: 12@ C13, 18@ C19 outlets; on 18@ 1-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 71mm x 89mm x 2030mm (2.8in x 3.5in x 79.9in). Max Weight 12 kg. Maximum ambient temperature 60C at full load.

 

  • Removable Controller
  • Securelock
  • Embedded Processor: ARM Cortex A5 500MHZ (Atmel A5D21C), 16MB SPI Flash, 128MB DDR2 RAM

Products specifications

Attribute name Attribute value
Height 79.9"
Load Capacity 52700 VA
Width 2.8"
Depth 3.5"
Mounting Vertical
Display LCD
Type Three-phase
Monitoring Humidity, Temperature
Block 1 output current 12 A
Block 2 output current 16 A
Technical details
Product color Black
Packaging data
Package height 86.5"
Package width 8.46"
Package depth 6.5"
Ports & interfaces
AC outlets quantity 30 AC outlet(s)
AC outlet types C13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports 2
USB ports quantity 3
Power plug IEC 320
Design
PDU types Monitored
Operational conditions
Operating temperature (T-T) 0 - 60 °C
Storage temperature (T-T) -25 - 65 °C
Operating relative humidity (H-H) 0 - 85 %
Storage relative humidity (H-H) 0 - 100 %
Operating altitude 0 - 72000"
Non-operating altitude 0 - 120000"
Power
Maximum current 80 A
Nominal input voltage 415 V
AC input frequency 50 - 60 Hz
Power protection features Overload
Features
Output voltage 220 - 240 V
Rack capacity 0U
LED indicators Status
Other features
Nominal output voltage 230 V
/* Added for Digitol */ /* End Added for Digitol */