Filter by attributes
  • Circuit breaker
Filter by manufacturer
Categories

Power Distribution Units (PDUs)

View as Grid List
Sort by
Display per page

Raritan PX3-5664U power distribution unit (PDU) 30 AC outlet(s) 0U Black

5922987
Raritan PX3-5664U. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L21-30P. Cable length: 118.1" (3 m), Certification: UL. Monitoring: Current, Power, Voltage, Supported network protocols: TFTP, DHCP, SSH(CLI). Nominal input voltage: 208 V, Maximum current: 30 A, Load capacity: 8600 VA

Panduit P36D29M power distribution unit (PDU) 36 AC outlet(s) 0U

12751850
Panduit P36D29M. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: CS8365C. Cable length: 118.1" (3 m)

APC AP7569 power distribution unit (PDU) Black

2015421
APC AP7569. Product color: Black. Input connection type: CS8365, Output connections: 24x IEC 320 C13 4x IEC 320 C19 2x NEMA L6-30R. Cable length: 35.8" (0.91 m), Certification: cUL Listed,CSA,METI Denan,UL 60950,UL Listed. Nominal input voltage: 208 V, Nominal output voltage: 208 V, Load capacity: 14400 VA. Dimensions (WxDxH): 2.17 x 3.74 x 70" (55 x 95 x 1778 mm), Weight: 16.1 lbs (7.32 kg)

APC IT Module power distribution unit (PDU)

2807375
APC IT Module. Output connections: 3 x IEC 309. Nominal input voltage: 400 V, Nominal output voltage: 230 V, Maximum input current per phase: 32 A. Dimensions (WxDxH): 17 x 5.98 x 5.98" (432 x 152 x 152 mm), Weight: 14.1 lbs (6.39 kg). Package dimensions (WxDxH): 17 x 5.98 x 5.98" (432 x 152 x 152 mm), Package weight: 16.1 lbs (7.3 kg)

Raritan PX3-5720U power distribution unit (PDU) 36 AC outlet(s) 0U Black

5460585
Raritan PX3-5720U. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L15-30P. Cable length: 118.1" (3 m). Monitoring: Current, Power, Voltage, Supported network protocols: TFTP, DHCP, SSH(CLI). Nominal input voltage: 208 V, Maximum current: 30 A, Load capacity: 8600 VA

Raritan PX3-1765V-V2 power distribution unit (PDU) 48 AC outlet(s) 0U Black

5412138
Raritan PX3-1765V-V2. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, Power plug: IEC 60309. Cable length: 118.1" (3 m), Certification: UL. Monitoring: Current, Power, Voltage, Supported network protocols: TFTP, DHCP, SSH(CLI). Nominal input voltage: 208 V, Maximum current: 60 A, Load capacity: 17300 VA

APC PDM3450CS50-500 power distribution unit (PDU) 1 AC outlet(s) Black

2695300
APC PDM3450CS50-500. PDU types: Metered, Monitored, Product color: Black. AC outlets quantity: 1 AC outlet(s), Output connections: 1 x CS50. Cable length: 196.9" (5 m), Certification: UL. Management platform: Web/SNMP. Nominal input voltage: 208 V, AC input frequency: 60 Hz, Nominal output voltage: 208 V

Eaton TPC2806 power distribution unit (PDU) 7 AC outlet(s) 1U Black

4524459
Eaton TPC2806. Rack capacity: 1U, Type: Single-phase, Mounting: Horizontal. AC outlets quantity: 7 AC outlet(s), AC outlet types: NEMA 5-15R, NEMA 5-20R. Nominal input voltage: 110 - 125 V, Maximum current: 24 A, AC input frequency: 50 - 60 Hz

APC IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 380cm power distribution unit (PDU) 1 AC outlet(s) Black

2859910
APC IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 380cm. PDU types: Metered, Monitored, Product color: Black. AC outlets quantity: 1 AC outlet(s), Output connections: 1 x IEC 309. Cable length: 149.6" (3.8 m), Certification: UL. Management platform: Web/SNMP. Nominal input voltage: 230 V, AC input frequency: 60 Hz, Nominal output voltage: 230 V

APC AP8865 power distribution unit (PDU) Black

2832858
APC AP8865. Product color: Black. Input connection type: NEMA L21-30P, Output connections: 36x IEC 320 C13 6x IEC 320 C19 2x NEMA 5-20R. Cable length: 72" (1.83 m), Certification: CSA C22.2 No. 60950,UL 60950-1. Nominal input voltage: 208 V, AC input frequency: 50 - 60 Hz, Nominal output voltage: 208 V. Dimensions (WxDxH): 2.2 x 1.73 x 70.5" (56 x 44 x 1791 mm), Weight: 16.7 lbs (7.56 kg)

Raritan PX3-5660V-C1 power distribution unit (PDU) 30 AC outlet(s) 0U Black

6635292
Raritan PX3-5660V-C1. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, NEMA 5–20R, Power plug: IEC 320. Cable length: 118.1" (3 m), Security algorithms: HTTPS, SSH. Monitoring: Current, Power, Voltage. Nominal input voltage: 208 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz

APC IT Power Distribution Module 3 Pole 4 Wire 50A CS50 440cm power distribution unit (PDU) 1 AC outlet(s) Black

2695299
APC IT Power Distribution Module 3 Pole 4 Wire 50A CS50 440cm. PDU types: Metered, Monitored, Product color: Black. AC outlets quantity: 1 AC outlet(s), Output connections: 1 x CS50. Cable length: 173.2" (4.4 m), Certification: UL. Management platform: APC InfraStruXure Manager. Nominal input voltage: 208 V, AC input frequency: 60 Hz, Nominal output voltage: 208 V

Raritan PX3-5525V-E2 power distribution unit (PDU) 24 AC outlet(s) 0U Black

6361809
Raritan PX3-5525V-E2. PDU types: Managed, Metered, Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Input connection type: NEMA L15-30P (3P4W). Cable length: 118.1" (3 m), Certification: UL, ICES-003, FCC. Monitoring: Humidity, Temperature. Nominal input voltage: 208 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz

Raritan PX3-5520R-E2 power distribution unit (PDU) 24 AC outlet(s) 2U Black

5524497
Raritan PX3-5520R-E2. PDU types: Monitored, Switched, Rack capacity: 2U, Type: Three-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: C13 coupler, Power plug: IEC 60320. LED indicators: Status, Cable length: 118.1" (3 m), Security algorithms: HTTPS, SSH. Monitoring: Current, Power, Voltage. Nominal input voltage: 208 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz

Raritan PX3-5924V-N1 power distribution unit (PDU) 32 AC outlet(s) 0U Black

6206039
Raritan PX3-5924V-N1. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 32 AC outlet(s), AC outlet types: NEMA 5-20R. Cable length: 118.1" (3 m), Security algorithms: HTTPS, SSH. Monitoring: Current, Power, Voltage. Nominal input voltage: 120 V, Maximum current: 20 A, AC input frequency: 50 - 60 Hz

Raritan PX3-5172V-N1 power distribution unit (PDU) 32 AC outlet(s) 0U Black

5650614
Raritan PX3-5172V-N1. PDU types: Managed, Metered, Monitored, Switched, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 32 AC outlet(s), AC outlet types: NEMA 5–20R, Input connection type: NEMA 5-20P (2P3W). Cable length: 118.1" (3 m), Certification: UL, FCC, ICES-003. Monitoring: Humidity, Temperature. Nominal input voltage: 120 V, Maximum current: 20 A, AC input frequency: 50 - 60 Hz

Raritan PX3-5524V-E2 power distribution unit (PDU) 24 AC outlet(s) 0U Black

6334406
Raritan PX3-5524V-E2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 118.1" (3 m). Monitoring: Humidity, Temperature. Nominal input voltage: 208 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz

Raritan PX3-5528V-V2 power distribution unit (PDU) 24 AC outlet(s) 0U Black

5076201
Raritan PX3-5528V-V2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 60309. Cable length: 118.1" (3 m). Monitoring: Current, Humidity, Power, Temperature, Voltage. Nominal input voltage: 400 V, Maximum current: 32 A, Nominal output voltage: 230 V