Tripp Lite PDUMV30. PDU types: Metered, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 24 AC outlet(s), AC outlet types: NEMA 5–15, NEMA 5–20R, Power plug: NEMA L5-30P. Cable length: 118.1" (3 m), Certification: UL60950-1 (USA, Canada), NOM (Mexico). Nominal input voltage: 100-127 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 2.19" (55.6 mm), Depth: 3.75" (95.2 mm), Dimensions (WxDxH): 2.24 x 3.74 x 63.8" (57 x 95 x 1620 mm)
Eaton T9092B-CBSF. PDU types: Basic, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 12 AC outlet(s), AC outlet types: C13 coupler, Power plug: C20 coupler. Nominal input voltage: 208-240 V, Maximum current: 16 A, AC input frequency: 50 - 60 Hz. Dimensions (WxDxH): 19 x 5 x 1.69" (482 x 127 x 43 mm)
Tripp Lite PDUMV40. PDU types: Metered, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 32 AC outlet(s), AC outlet types: NEMA 5–15R, NEMA 5–20R, Input connection type: NEMA 5-20P, NEMA L5-20P. Cable length: 120.1" (3.05 m), Certification: UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada). Nominal input voltage: 100-127 V, Maximum current: 40 A, AC input frequency: 50 - 60 Hz. Width: 1.5" (38.1 mm), Depth: 3.34" (84.8 mm), Dimensions (WxDxH): 71.3 x 1.5 x 3" (1809.8 x 38.1 x 76.2 mm)
Eaton TPC2234-A2. PDU types: Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 8 AC outlet(s), AC outlet types: NEMA 5–20R, Power plug: NEMA 5–20P. Cable length: 78.7" (2 m). Nominal input voltage: 120 V, Maximum current: 16 A, AC input frequency: 50 - 60 Hz. Dimensions (WxDxH): 19 x 4.49 x 1.69" (482 x 114 x 43 mm)
Tripp Lite PDUMH15ATS. PDU types: Metered, Switched, Rack capacity: 1U, Type: Single-phase. AC outlets quantity: 8 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 5–15P. Cable length: 144.1" (3.66 m). Nominal input voltage: 120 V, Maximum current: 15 A, AC input frequency: 50/60 Hz. Width: 17.5" (444.5 mm), Depth: 14.5" (368.3 mm), Height: 1.75" (44.4 mm)
Eaton T2235-F4-CNB09L. PDU types: Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 6 AC outlet(s), Power plug: NEMA L6-30P. Cable length: 78.7" (2 m). Nominal input voltage: 208-240 V, Maximum current: 24 A, AC input frequency: 50 - 60 Hz. Dimensions (WxDxH): 19 x 9.49 x 1.69" (482 x 241 x 43 mm)
Vertiv VHVRCN122-102D20TL6. PDU types: Metered, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 12 AC outlet(s), AC outlet types: NEMA L6-20R, Power plug: NEMA L6-20P. Cable length: 120.1" (3.05 m), Certification: RoHS Compliant UL & c-UL Listed 60950. Monitoring: Current, Voltage. Nominal input voltage: 200-240 V, Maximum current: 20 A, AC input frequency: 50/60 Hz
Tripp Lite PDUMV30HV. PDU types: Metered, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L6-30P. Cable length: 120.1" (3.05 m), Certification: UL60950-1 (USA, Canada), NOM (Mexico). Nominal input voltage: 208-230 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 3.5" (88.9 mm), Depth: 2.25" (57.2 mm), Dimensions (WxDxH): 2.24 x 3.74 x 63.8" (57 x 95 x 1620 mm)
Eaton T8S-A-CB-SF. PDU types: Basic, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 8 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: C20 coupler. Nominal input voltage: 120 V, Maximum current: 12 A, AC input frequency: 50 - 60 Hz. Dimensions (WxDxH): 19 x 6.97 x 1.69" (482 x 177 x 43 mm)
Eaton TPC2234-A-F. PDU types: Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 8 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 5–15P. Cable length: 78.7" (2 m). Nominal input voltage: 120 V, Maximum current: 12 A, AC input frequency: 50 - 60 Hz. Dimensions (WxDxH): 19 x 4.49 x 1.69" (482 x 114 x 43 mm)